DC 30 Ton Refrigeration Only System

DC 30 Ton Refrigeration Water Chiller


Construction Features                                                                                                       Configuration

Environmentally Friendly R-404ALow                                                                           Ambient Fan Cycling

Top Discharge Condenser Exhaust                                                                                Low Ambient Flooded Condenser Includes Receiver with Isolation Valves (Optional)

Control Panel with Hinged Door                                                                                      Brazed Plate or Shell and Tube Evaporator

Insulated Copper Piping                                                                                                      Condenser Ambient Fan Cycle Control

G-90 Galvanized Cabinetl                                                                                                   Suction Line Filter-Dryer

Power Terminal Block with Single Point Electrical Connection                        Liquid Line Filter–Drier

Spring Mounted Compressors                                                                                         Thermal Expansion Valve

Service Valves                                                                                                                           Digital Control Thermostat

                                                                                                                                                           Suction and Liquid Vibration Eliminators

Refrigerant & Electrical Safety Controls                                                                 Dual or Single Copeland Discus Compressors

Low Water Flow Safety Shut-Off                                                                                     Cylinder Unloading (Optional)

Short Cycling Time Delay                                                                                                    Compressor Staging For Dual Compressors (Optional)

Low Refrigerant Pressure Control                                                                                  Pump Down Solenoid

High Refrigerant Pressure Controlwith Manual Re-Set

Freeze-Stat with Manual Re-Set                                                                                    Testing

Temperature Sensor Failure Protection                                                                     UL/CUL Listed All Models

Compressor Crankcase Heater                                                                                      Leak Detection, Dielectric and Run Test

Control Circuit Fuses

Sentronic Oil Safety Switch

Water Inline Strainer


Electrical Specifications

DC 30 Ton Refrigeration Only System
Diagram Of 30 Ton Refrigeration Only System